<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Iranian Sustainable Building Scientific Association</PublisherName>
				<JournalTitle>International Journal of Urban Management and Energy Sustainability</JournalTitle>
				<Issn>2538-1628</Issn>
				<Volume>7</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>07</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Evaluating the Impact of the Spatial Scale of Central Courtyards on Outdoor Thermal Comfort in High-Density Residential Complexes (Case Study: The Hot and Dry Climate of Shiraz City)</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>289</FirstPage>
			<LastPage>309</LastPage>
			<ELocationID EIdType="pii">741521</ELocationID>
			
<ELocationID EIdType="doi">10.22034/ijumes.2026.2097300.1391</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Ali Akbar</FirstName>
					<LastName>Raoufat</LastName>
<Affiliation>Department of Urban Planning and Architecture, Yas.C., Islamic Azad University, Yasuj, Iran</Affiliation>
<Identifier Source="ORCID">0009-0008-7857-0528</Identifier>

</Author>
<Author>
					<FirstName>Ali Akbar</FirstName>
					<LastName>Heidari</LastName>
<Affiliation>Department of Technical and engineering, Yasouj university, Yasouj, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-2188-1850</Identifier>

</Author>
<Author>
					<FirstName>Abdolhossein</FirstName>
					<LastName>Paknejadi</LastName>
<Affiliation>Department of Civil Engineering, Yas.C., Islamic Azad University, Yasuj, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-9843-3976</Identifier>

</Author>
<Author>
					<FirstName>Hamid</FirstName>
					<LastName>Eskandari</LastName>
<Affiliation>Department of Technical and engineering, Yasouj university, Yasouj, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-1598-7421</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>06</Month>
					<Day>09</Day>
				</PubDate>
			</History>
		    <Abstract>Optimizing the microclimatic behavior of outdoor spaces in high-density residential fabrics is one of the most effective strategies for mitigating human thermal stress and enhancing urban sustainability in hot and dry climates. Aiming to analyze the impacts of geometry, scale, and spatial organization on outdoor thermal comfort, this study evaluates 18 layout scenarios generated by combining four central courtyard typologieswithin a high-density residential complex in Shiraz. The evaluations were conducted under the most critical summer conditions using numerical microclimate simulations. The analytical findings reveal that transitioning from the large-scale, single-courtyard reference model to fragmented and decentralized spatial configurations consistently leads to a reduction in air temperature and mean radiant temperature (Tmrt), thereby improving the Physiological Equivalent Temperature (PET) index across all scenarios. Analyzing the thermodynamic mechanisms governing the spaces indicates that the radiative load (Tmrt) is the primary driver of thermal perception in this climate. The fine-grained square and medium-sized rectangular typologies exhibit the most successful performance in mitigating solar radiative energy and lowering the PET index, primarily due to the reduction of the Sky View Factor (SVF) and the creation of self-shading by the physical built form. Conversely, spacious courtyards transform into thermal traps owing to their low degree of enclosure. Regarding wind flow and relative humidity components, although elongated geometries offer better aerodynamic potential for airflow passage, the minor reduction in wind velocity in fine-grained fabrics due to physical roughness is entirely negligible when compared to the positive effects of shading on mitigating the radiative load. Ultimately, this research emphasizes that the smart combination of compact and linear fine-grained layouts represents the most effective design strategy for achieving sustainable outdoor thermal comfort in residential complexes within hot and dry regions.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">central courtyard</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">ENVI-met</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Hot and Dry Climate</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Outdoor thermal comfort</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Physical scale</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Physiological Equivalent Temperature (PET)</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.ijumes.com/article_741521_3ad757d7253dc772dc78abce5c80a90a.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
